5 Stage R.O. Filtration System
■ 5-micron sediment poly block pre-filter to filter suspended particles such as dirt, sand, rust, etc.
■ Carbon block to reduce free chlorine, chloramines, chlorine taste and odor.
■ 75gpd R.O. membrane encapsulated element to reduce dissolved solids, metal ions, bacteria and viruses, and other suspended particles as small as 0.0001 micron. NSF-certified TFC sheet by Toray®, Japan.
■ Two-stage water conditioning combo post-filter.
Key Features:
■ Clean and safe drinking water right in your home. No need to transport and dispose of bottled water any more.
■ Factory-preinstalled filters and membrane for faster and easier setup.
■ Filters and membrane quick-change housings for easy regular maintenance.
■ Compact and beautiful design.
■ Automatic flush valve: for peak performance and healthier membrane. 18 seconds of powerful flush at the end of each water filtration cycle prevent the scale and debris buildup on the membrane outer surface.
■ The booster pump increases pressure to radically improve the performance and effectiveness of the R.O. unit in all three key areas: increases filtered water flow (production rate), increases rejection rate (improves water purification quality), increases recovery rate (decreases amount of waste water).
■ Prolongs the membrane and pre-filter(s) service life due to increased recovery rate.
■ Fully automatic operation of the pump box unit: just open the faucet and get clean water instantly; automatic shut off and flush.
■ LED indicators: easily understand what the state of your R.O. unit is.
■ Split, flexible installation possible where needed: install the pump box up to 50 feet away from the R.O. unit itself. Useful for the situations like lack of space or lack of electrical outlet under the sink, or moving the unit to more appropriate place.
■ Idling protection: if you forget to shut off the filtered water faucet for a long time the pump will shut down automatically for you.
■ Full separation of electrical components from the membrane and filters of the main R.O. unit makes the regular servicing of your R.O. machine both easy and safe: no need to worry about electrical valves and wires while changing your water filters or membrane.
■ Quick fittings for easy tube connections and change of filters.
Specification
Operating requirements:
■ Minimum supply water pressure: 7.25 psi (0.05 MPa)
■ Maximum supply water pressure: 80 psi (0.55 MPa)
■ Minimum water temperature: 41 oF (5 oC)
■ Optimal water temperature: 59–77 oF (15–25 oC)
■ Maximum water temperature: 95 oF (35 oC) / up to 105 oF (40.5 oC) short-term
■ Ambient air temperature: 41–105 oF (5–40.5 oC)
■ Water source: tap water supply, chlorinated or non-chlorinated, bacteriologically safe
■ Supply water pH range: 4.0-11.0
■ Supply water turbidity: < 1 NTU
■ Supply water components: Hardness (CaCO3) <180 mg/L (<10.5 gpg), Iron <0.1 mg/L, Manganese <0.05 mg/L, Hydrogen Sulfide 0.00 mg/L
■ Maximum supply water TDS: 1000 ppm
■ Indoor use only.
■ Electrical input: AC 100-240V 50/60 Hz
■ Maximum length of the line between the pump unit and the membrane (“split installation”): 50 ft (15 m) (purchase of extra tubing may be required)
■ Tubing: ¼”
Performance:
Performance of the appliance such as filtered water delivery rate, rejection rate, etc. is highly dependent on local conditions (inlet water pressure, temperature, TDS and degree of contamination, tank air pressure, etc.) and R.O. system use pattern. Actual performance may vary.
■ Filtered water production rating: 75 gpd (270 lpd) maximum
■ Filtered water delivery rate (from the tank), typical: 0.27–0.74 gpm (1–2.8 l/min)
■ Membrane rejection rate1, typical: 90%
■ Recovery rate (system efficiency2), typical: 15%
■ Drain water flow restrictor: 300 cc (ml/min) nominal, up to 360 cc in working mode, open flow in flush mode.
■ Auto-flush duration: 18±5% s
■ Tank Storage Capacity (Total Volume): up to 2.5G (4.0G)
■ Tank full refill time, typical: 35-45 min
■ Idling protection: 120 minutes (the pump box unit shuts down the pump and goes into ‘reset required’ mode if working mode continuous duration reaches 2 hours without interruption)
Weight and size:
Pump box unit:
Size (WDH), body only, excluding protrusions: 8.74 x 4.80 x 12.44” (222 x 122 x 316 mm)
Weight, without water and tubing: 8.6 lbs (3.9 kg)
R.O. filtration unit:
Size (WDH), body only, excluding protrusions: 13.46 x 3.35 x 14.80” (342 x 85 x 376 mm)
Weight, without water and tubing: 8.8 lbs (4.0 kg)
Storage tank:
Size (WDH), body only, excluding protrusions: 10.55 x 10.55 x 14.90” (268 x 268 x 378 mm)
Weight, without water and tubing: 6.0 lbs (2.7 kg)
Warranty:
1 year worldwide limited warranty (+ local regulations if applicable)
Package contents:
The auto-flush booster pump box unit
The R.O. filtration unit
Storage tank
Universal worldwide adapter ball valve (G1/2” - G3/8” - UNEF 9/16”-24 - JG 1/4”)
Teflon tape roll
Faucet (depending on SKU)
Drain saddle
Wrench
¼” tank valve
(26 ft / 8 m) Water tubing ¼”
¼” x ¼” union check valve
(2) ¼” x ¼” x ¼” union tee fitting
User’s guide
1 For all dissolved solids combined as measured by TDS or conductivity meter.
2 Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.